Synthes distal fibula inventory

LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°)..

The best jewelry inventory software can track stones, findings, and finished products, plus purchase ordering and more. See our top picks. Retail | Buyer's Guide REVIEWED BY: Meagh...Synthes Stainless Steel Right LCP Posterolateral Distal Fibula Plate ... Surplus Inventory Form; Contact Us; FAQs; Government; Our Company; Our History; Meet Our Team ... Account . SYNTHES: 02.112.108. Quantity Available:0. LCP Posterolateral Distal Fibula Plate, 2.7/3.5 mm Size, 90 mm Length, Stainless Steel, 4-Hole, Right Version, Single-Use ...

Did you know?

Additional Info. Unit of Measurement: Each. Catalog Number: 01.112.077. Set includes an assortment of instruments, implants and a storage case. CLICK HERE for list of contents. Examples of plates and instruments (depth gauge) shown below. Trials available. Photo is representative—please contact your sales rep for more complete details.The VA-LCP Lateral Distal Fibula Plate will also be available for surgeons in titanium after a sequential market introduction starting at the end of 2020. In addition, a new anatomic tray will be introduced for the Universal Small Fragment (USF) System which can be stocked with stainless steel or titanium VA-LCP Lateral Distal Fibula Plates.Inventory Control Form Variable Angle LCP Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 02.115.630 3 41 +90° 02.115.631 3 41 –90° 02.115.640 4 49 +90° 02.115.641 4 49 –90° 2.4 mm VA LCP Dorsal Distal Radius L-Plate, 2 holes headInventory Control Form Titanium Variable Angle LCP Distal Radius Plates 2.4 mm Titanium VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 04.115.630 3 41 +90° 04.115.631 3 41 -90° 04.115.640 4 49 +90° 04.115.641 4 49 -90° 2.4 mm Titanium VA LCP Dorsal Distal Radius L-Plate, 2 holes head Shaft

Fluoroscopic images show the technique. After introducing the plate through a small incision (a), cortical screws were inserted on the distal hole ② and the elongated hole ① (b).A bone holding clamp was used to compress the cortical screw and the drill sleeve locked to the plate ③.When the clamp was compressed, the distal fragment could be pushed downward (black arrow) to restore fibular ...Our LCP™ Hook Plate is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plate features pointed hooks to aid in plate placement and holes for both lag screws and locking screws. Product Specifications. How to Use This Product.The LCP™ Pilon Plate is part of the locking compression plate system and was designed with the following key features: Combi holes that combine a dynamic compression unit with a locking screw hole. Shaft holes that accept 3.5 mm locking screws, 3.5 mm cortex screws, and 4.0 mm cancellous bone screws. A distal portion and arms that may be ...Locking Distal Fibula Plates, Right QTY PRODUCT # HOLES PRICE LOT# UDI AR-9943BR-04 4 AR-9943BR-05 5 AR-9943BR-06 6 ... Inventory Control Form Author: Arthrex, Inc.

Distal Humerus Plates Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates2 DePuy Synthes 2.4 ®mm Variable Angle LCP Distal Radius System Surgical Technique. 2.4 MM VARIABLE ANGLE LCP DISTAL RADIUS SYSTEM. Plate features. Three head sizes accommodate . patient anatomy. • Narrow – 6-hole head (19.5 mm) • Standard – 6-hole head (22 mm) – 7-hole head (25.5 mm) • Anatomically contoured volar distalThe distal radius and distal ulna form a three-column biome-chanical construction 3: – The ulnar column is the distal ulna, the triangular fibrocar-tilage and the distal radio-ulnar joint. – The intermediate column is the medial part of the distal radius, with the lunate fossa and the sigmoid notch. ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Synthes distal fibula inventory. Possible cause: Not clear synthes distal fibula inventory.

The distal tibia plating system has been designed for versatile treatment of all distal tibial fracture patterns. The comprehensive plate ofering gives surgeons the freedom to choose the most appropriate surgical approach for each patient. The implants have been designed to specifically address each of the variable fracture patterns commonly ...The VA LCP™ Ankle Trauma System 2.7/3.5 is part of Synthes Distal Tibia Plates family and consists of the following systems: VA LCP Medial Distal Tibial Plate 2.7/3.5. VA LCP Anteromedial Distal Tibial Plate 2.7/3.5. VA LCP Anterolateral Distal Tibial Plate 2.7/3.5. VA LCP Posterolateral L- and T-Plates 2.7. Get in Touch with a Sales Consultant.Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4/2.7, Extra-long Variable Angle LCP Volar Rim Distal Radius Plate 2.4 Variable Angle Locking Hand System Please read these instructions for use, the Synthes brochure“Important Informa-tion” carefully before use.

LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°).The A.L.P.S. Fibula Plating System aims to make it ideal for simple or complex fibula fracture procedures that involve minimal tissue coverage. The low-profile titanium plate metallurgy and multiplanar locking screw technology enable the formation of the three-dimensional matrix of fixed and variable angle screws to create a true subchondral ...This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.

whitleys funeral home Edit Synthes va ankle inventory. Quickly add and underline text, insert images, checkmarks, and symbols, drop new fillable areas, and rearrange or delete pages from your document. Get the Synthes va ankle inventory completed. Download your updated document, export it to the cloud, print it from the editor, or share it with other people through ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ... lowes dryer vent boxramey shortridge funeral home obituaries Locking screws serve to provide stability to comminuted, unstable me- taphyseal fractures or in osteopenic bone. The A.L.P.S. Fibula Plating System is intended for the fixa- tion of fractures, osteotomies and non-unions of the fibula, malleolus, distal tibia, metatarsals, scapula, clavicle, distal humerus and humeral head, olecranon, ulna ...Trauma | March 2021. New VA-LCP Lateral Distal Fibula Plates in titanium and associated anatomic tray for the Universal Small Fragment System. Trauma Home. In 2013 the Variable Angle LCP Ankle Trauma 2.7/3.5 system was approved by the AO TC Trauma. police beat jacksonville il today Device Name: Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates Indications for Use: The Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates are indicated for fractures, osteotomies, and non-unions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone. Prescription Use X AND/OR Over-The-Counter UseFibular allografts have recently been used in the repair of complex periarticular fractures of the proximal tibia and distal femur. Fibular allografts can be inserted in a variety of manners to achieve goals specific to each individual fracture pattern. ... A Synthes 4.5mm distal femoral locking plate was reduced to bone distally with a ... whippoorwill holler net worthsam ponder basic instinctdecorating christmas bottles For larger patients, or when high weight bearing is expected, additional stability can be achieved by adding a carbon fiber rod between the most distal and the most proximal Schanz screw. Product Information. Product Name. Synthes Large External Fixator Set - 115.720. Manufacturer. olathe power outage The FIBULINK Syndesmosis Repair System provides a repair solution for ankle fractures of the syndesmosis. It is compatible with all DePuy Synthes distal fibula plates and is packaged in sterile, single-use packaging. This system features: Stainless steel or titanium implants. Tibia Screw.3.5 mm. Remove the cortex screw from hole 1 and replace it with a bicortical, self-tapping locking screw. Screw the drill sleeve exactly into the threaded part of the combi-hole and drill the hole with the LCP drill bit 4.3 mm. Determine the screw length and insert the screw as described on page 15. trump mugshot wallpaperhanes lineberry funeral home greensboro nc205 doubler – The two angled locking holes distal to the plate head accept a 5.0 mm cannulated locking screw or 5.0 mm cannulated conical screw to secure the plate position. The hole angles allow the locking screws to converge with two of the three screws in the plate head. – Combi holes, distal to the angled locking holes, combine a DCU holeThe A.L.P.S. Fibula Plating System aims to make it ideal for simple or complex fibula fracture procedures that involve minimal tissue coverage. The low-profile titanium plate metallurgy and multiplanar locking screw technology enable the formation of the three-dimensional matrix of fixed and variable angle screws to create a true subchondral ...